AM2 Orthopedic System Features
Ideal for the clinic, group and private practice, these reliable, versatile systems are an outstanding value in Orthopedic radiography.
Float Top Table
The AM2 system consists of a float top table that is 31” (79 cm) in height with a welded steel pedestal base that facilitates patients weighing up to 400 lbs. (182 kg).
Table feature a generous table top workspace, allowing for comfortable and easy patient positioning. Precision stainless steel ball bearings float the table top in four directions. The heavy-duty table top locks provide a stable surface for fast and safe transfer of patients even during power outages. The recessed foot controls within the table base permit hands-free operation, while restricting inadvertent patient release.

Orthopedic Tubestand
The design of this rugged tubestand provides the maximum versatility needed for Orthopedic imaging. Extension of the tubestand beyond the table at either end in addition to angulating the x-ray tube facilitates chest exams and other off-table procedures. Transverse positioning of the tube off-center of the table midpoint (+/- 5”) is complimented by a centering detent for fast, precise repositioning of the tube.

Full Travel Wallstand
A precision bearing system provides effortless vertical travel of the stationary grid cabinet or optional reciprocating bucky. Accommodating up to a 14” x 17” (35 cm x 43 cm) cassette in either direction, the wallstand allows a broad range of procedures including weight-bearing exams.
Spectra 30HF High Frequency Generator
Manual Mode
Offering fast 2-point selection of only the kVp and mAs factors, the generator will automatically select the highest mA station and the shortest exposure time — resulting in less image blur caused by patient motion. The large LCD window displays the kVp, mAs and mA station, allowing modifications to be made prior to the x-ray exposure.
- 30kW
- 300mA @ 100kVp
- kVp range & selections: 40-125kVp
- mA Range Selections: 50s, 100s, 150L, 200L, 250L, 300L
- mAs Range: 0.5 - 400
- Power requirements: 230-250 VAC 1 Phase
- DOM 2014
AP (Anatomical Programming) Mode
This helpful feature (optional on the 30HF) offers, effortless images by fast, automatic techniqueselection in three easy steps:
1. Select the anatomical region.
2. Select the radiographic view.
3. Select the patient centimeter thickness.
For greater flexibility, the AP program can be modified and the changes saved to memory. Customized AP menus and parameters can be saved.
Professional de-installed - Inquire for Freight Costs